Concise Motion Systems
Home  | About Us  | Products  | Brands  | Applications  | Repairs  | Parts  | Contact Us  | Search    
 
innovative compact motion solutions
 
   
Linear Actuators
Rotary Actuators
Gearmotors
PushPull Chain
Screw Jacks
Worm Gears
New Products

MR6

MS12

MR30

AG60

AG60+

ESA

 

Compacta AG60 Gear Motor
Printable Documentation [pdf]

AG60: General Specifications

Limit Switch Options

Dimensions mm (inches)

   

Dimensions mm (inches)

Options with dimensions [mm]
a(mm)
b(mm)
a(in)
b(in)
Single phase AC motor
(-)
(-)
(-)
(-)
DC motor
430
(-)
16.9
(-)
Motor disc brake
435
(-)
17.1
(-)
Hand crank
486
(-)
19.1
(-)
Limit switch version 1 / 3 / 2P / ESA
(-)
209
(-)
8.2
Single or double ended stub shaft
(x)
(x)
(x)
(x)
Mounting plate (torque support)
(x)
(x)
(x)
(x)
Mounting angle
(x)
(x)
(x)
(x)
Stainless steel hollow shaft 1.4104
(-)
(-)
(-)
(-)
(-) causes no size alteration
(x) Please refer to the datasheets for additional or missing dimensions.

3-phase AC motors - 3x230/460V-60Hz

Output speed
Output torque
Output torque
Transmission
Motor speed
Motor output
Motor output
Self
Max. limit
switch range
RPM
Nm (60% duty cycle) ²
in-lbs (60% duty cycle) ²
ratio
RPM
kW
hp
locking
Output
rotation ¹
48.0
175
1548.9
69.7:1
3360
1.32
1.8
So
275
24.0
330
2920.7
139.5:1
3360
1.32
1.8
So
275
15.6
485
4292.6
220.8:1
3360
1.32
1.8
So
275
11.2
575
5089.2
302.2:1
3360
1.32
1.8
So
275
8.4
600
5310.4
395.2:1
3360
1.32
1.8
Ss
275
6.0
600
5310.4
558.0:1
3360
1.32
1.8
Ss
275
4.6
600
5310.4
732.4:1
3360
1.32
1.8
Sd
275
3.0
600
5310.4
558.0:1
1680
0.72
1.0
Ss
275
2.3
600
5310.4
732.4:1
1680
0.72
1.0
Sd
275
1.1
450 (40%) *
3982.8 (40%) *
732.4:1
840
0.28 (40%) *
0.37 (40%) *
Sd
275

¹Please ask for max. limit switch range of ESA.
² At 100% duty (continuous duty), a cooling fan is required. With cooling, motors rated at 60% duty can be operated at 100% duty.
* 40% duty cycle.

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

Single phase AC motors - 1x230V-60Hz, 110V-60Hz

Output speed
Output torque
Output torque
Transmission
Motor speed
Motor output
Motor output
Self
RPM
Nm (40%
duty cycle) ³
In-lbs(40%
duty cycle) ³
ratio
RPM
kW
hp
locking
48
79.2
700.7
69.7:1
3360
0.66
0.89
So
24
146.7
1298.1
139.5:1
3360
0.66
0.89
So
15.6
218.3
1932.4
220.8:1
3360
0.66
0.89
So
11.2
258.3
2286.4
302.2:1
3360
0.66
0.89
So
8.4
311.7
2758.5
395.2:1
3360
0.66
0.89
Ss
6
355.8
3149.4
558.0:1
3360
0.66
0.89
Ss
4.6
416.7
3687.8
732.4:1
3360
0.66
0.89
Sd
3
385.8
3414.9
558.0:1
1680
0.36
0.48
Ss
2.3
452.5
4004.9
732.4:1
1680
0.36
0.48
Sd

¹Please ask for max. limit switch range of ESA.
² The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalogue torqu
Please contact Concise Motion Systems in case maximum torque is required.

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

24V DC shunt wound motor

 
Output speed
Output torque
Output torque
Self locking
Transmission
RPM
Nm
in-lbs
 
ratio
27
108
955.9
So
69.7:1
14
193
1708.2
So
139.5:1
9
282
2495.9
So
220.8:1
6
365
3230.5
So
302.2:1
5
404
3575.7
Ss
395.2:1
3.5
466
4124.4
Ss
558.0:1
2.6
562
4974.1
Sd
732.4:1

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

P = 0,45 kW, IN = 28A, 30% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.

Notes:

Load Capacity of the output shaft: Radial load - 2000N, Axial load - 1000N

The gear motor can be overloaded by 50% for brief periods. Single-phase AC- and DC motors may stall.

Please contact Concise Motion Systems in case of the following operating conditions:

  • Temperatures below 0°C (single phase AC and DC motors: below 10°C)
  • Temperatures above 40°C
  • Strong vibrations

 
 
 
 

General Terms & Conditions

 

Home Rotary Actuators